Vennligst vent...
Produktet ble lagt i handlekurven. Se handlekurven her
Tom handlekurv

JUNIPER EX4200 EX3200 2-PORT 10G SFP+ 4-PORT 1G SFP UPLINK MODULE

Forsiden Kommunikasjon Svitsjer JUNIPER EX4200 EX3200 2-PORT 10G SFP+ 4-PORT 1G SFP UPLINK MODULE
JUNIPER EX4200 EX3200 2-PORT 10G SFP+ 4-PORT 1G SFP UPLINK MODULE (EX-UM-2X4SFP)

JUNIPER EX4200 EX3200 2-PORT 10G SFP+ 4-PORT 1G SFP UPLINK MODULE

Varenr.:
EX-UM-2X4SFP
EAN:
0832938043343
  • Produkt Modul
  • Porter 2
  • Hastighet 10Gbps
10 968,-
13 710,- inkl. mva
LEASING (ekskl. mva)
24-mnd 
539,-/mnd
36-mnd 
402,-/mnd
48-mnd 
332,-/mnd
60-mnd 
291,-/mnd
Ved Leasing gjelder: Etableringsgebyr 0,-, faktureringsgebyr 0,-/mnd, minimumsordre 0,-. Frakt og mva. kommer i tillegg. Forutsetter kredittgodkjenning. Leasing kan velges som en betalingsmåte når du går til kassen.
Beskrivelse

New EXUM2X4SFP 2-Port 10G SFP+ / 4-port 1GP SFP UPLINK MODULE EX4200/3200

EX 3200 and EX 4200 switches support three types of uplink modules:

SFP uplink module—Provides four ports for 1-gigabit small form-factor pluggable (SFP) transceivers.
SFP+ uplink module—Provides two ports for 10-gigabit small form-factor pluggable (SFP+) transceivers when configured to operate in 10-gigabit mode or four ports for 1-gigabit small form-factor pluggable (SFP) transceivers when configured to operate in 1-gigabit model.
XFP uplink module—Provides two ports for 10-gigabit small form-factor pluggable (XFP) transceivers.

You can use the optional uplink module ports to connect an access switch to a distribution switch. You can also use these ports to connect members of a virtual chassis across multiple wiring closets.
When connecting uplink module ports, you can install an SFP uplink module at one end and install an SFP + uplink module configured to operate in the 1-gigabit mode at the other end. Likewise, you can install an XFP uplink module at one end and install an SFP + uplink module configured to operate in the 10-gigabit mode at the other end.

Note: On an EX 3200 switch, if you install a transceiver in an SFP uplink module, a corresponding network port from the last four built-in ports is disabled. For example, if you install an SFP transceiver in port 2 on the uplink module (ge-0/1/3), then ge-0/0/23 is disabled. The disabled port is not listed in the output of show interface commands.

Selv om vi gjør vårt beste for å gi relevant informasjon, så er bildene kun for å gi et generelt inntrykk, og selve varen er ikke nødvendigvis akkurat slik som avbildet. Dersom det er forskjeller mellom produktoverskrift, beskrivelse og bilde, så er det produktoverskriften som gjelder (f.eks. PCer kommer ikke nødvendigvis med skjerm selv om bildet viser det). Hvis noe er uklart, vennligst send epost til kundestøtte før du bestiller. Vi tar forbehold om trykkfeil og endring av priser og spesifikasjoner uten varsel.